Metered, Outlet Switch PDUs (EN2000 Series)

Remote outlet on/off switching for power-up sequencing, remote power cycling and outlet use management combined with all features of the EN1000 Series.

Make an Enquiry Alternate Enclosures

     Dimensions (mm) 
Catalogue No.Input CircuitMax PowerTotal OutletsLengthWidthDepthMax. chassis depth at breaker (mm)
ARPREN21011-Phase16A3.84kVA121065555050
ARPREN210532A7.68kVA221730555062
ARPREN211332A7.68kVA241826555062
ARPREN210332A7.68kVA241730555062
ARPREN210232A7.68kVA321826555080
ARPREN21103-Phase16A11.52kVA2417305550n/a
ARPREN211132A23.04kVA241826555080
ARPREN211232A23.04kVA241826555080

Application

Distribution of power inside a data centre environment where a variety of different power connectors are required.

Features

PDU Energy Metering and Monitoring

  • PDU level watt-hour energy metering (kWh)
  • PDU level power measurements (W)
  • Input phase level power measurements (V,A, VA, kWh, pf)
  • Circuit breaker level current measurements
  • High-accuracy, billing-grade metering capabilities
  • Embedded memory log to record/view/report historical data
  • User customisable alarm thresholds & notifications

Outlet Level Switching

  • Remote on/off power control by individual outlet
  • User-defined power on time delay to sequence IT equipment
  • Automatic sequencing to avoid inrush current overload
  • Outlet level user security with assignable roles and user access

Design

  • Low profile, space saving design
  • Ultra low profile circuit breakers on most models
  • Adjustable too-less mounting system
  • Colour coded and locking IEC receptacles and locking power cord compatible
  • Field rewireable input cord for front or top mounting

Environmental & Security Management

  • Optional Plug & play external environmental sensors including temperature, humidity, dry contact and water leak
  • Rack access monitoring with door contact switch
  • User customisable alarm thresholds and notifications

Network Management and Local Display Interface

  • Fully featured network management and altering capabilities supporting HTTP, HTTPS, SSH, Telnet, SNMP, Syslog and email
  • Strong encryption, passwords and advanced authorisation options including local permissions, LDAP/S and Active Directory
  • Daisy chain up to 4 rack PDUs and 24 environmental sensors through a single IP address
  • Largest in class, high visibility, oLED display

Circuit Breaker Status Monitoring

  • Active monitoring and alarming of circuit breaker on/off status

Compliance Approvals

  • AS/NZS3123
  • EN/IEC60950-1 Safety
  • CE approval
  • ROHS, WEEE environmental approvals

PDU Brackets

    Product Information
No. of PDUs To suit cabinet width (mm) Ausrack Plus Ausrack TxD Ausrack CQr
1 600 ARPDUBRK600 ATPDUBRK600 ACPDUBRK600
2 800 ARPDUBRK800 ATPDUBRK800 ACPDUBRK800